Repaired Leak on Liquid Line Caused by Rubbing as previous installer looped line set three times and then into penetration and the rubbing of line set against each other slowly ate away at the copper and produced a leak on 1/3/24 in Mansfield Texas. Near FM157 Mansfield, Texas 76063 Check out the Areas We Serve…
Read more
Clock is Pretty Hard to Move Freely
Clock is pretty hard to move freely. I removed and replaced defrost timer on 12/18/23 in Mansfield Texas. Near FM157 Mansfield, Texas 76063 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerate.com/areas-we-serve/ [spacer][SHORTCODE_ELEMENTOR id=3540]
Read more
Unit Had a Major Leak When I Arrived
Unit had a major leak when I arrived. I could still hear it blowing when I got there. Didn’t take me long to find. Was able to solder the leak and checked around the area for other leaks. Pulled vacuum and charged system with 404a instead of 407a on 12/7/23 in Arlington Texas. Near E…
Read more
Plug Harness Connection Came Loose
Plug harness connection came loose. I fixed the wiring and then verified that everything was in good working order on 12/1/23 in Arlington Texas. Near E Park Row Dr. Arlington, Texas 76010 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerate.com/areas-we-serve/ [spacer][SHORTCODE_ELEMENTOR id=3540]