Unit was frozen over. After I thawed unit out found evaporator was dirty and clogged full of debris. I cleaned evaporator coil started it up verified charge and watch box go down from 50 to 40. all ops normal at this time on 9/5/24 in Fort Worth Texas. Near N Collins St Arlington, TX 76011…
Read more
Capacitor Blown and Burnt Wiring
Capacitor blown and burnt wiring. Made wiring repairs and replaced capacitor. started unit up verified operation all ops normal at this time on 8/23/24 in Fort Worth Texas. Near Bryant Irvin Rd Fort Worth, TX 76132 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerate.com/areas-we-serve/ [spacer][SHORTCODE_ELEMENTOR id=3540]
Read more
Evaporator Motor Sluggish
Evaporator motor sluggish. Removed and installed new evaporator fan motor. Cold case getting to temp now on 8/21/24 in Fort Worth Texas. Near Tracewood Way Fort Worth, TX 76244 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerate.com/areas-we-serve/ [spacer][SHORTCODE_ELEMENTOR id=3540]
Read more
Kitchen AC Had Hole in the Evaporator
Kitchen AC had hole in the evaporator. Welded hole and then began to pull vacuum. after reaching 450 microns, charged unit with 14lbs of r410, started unit up verified operation on 8/20/24 in Fort Worth Texas. Near N Beach St Fort Worth, TX 76137 Check out the Areas We Serve and jobs we are doing…
Read more